RESEARCH ON OUR SITE
 
 

Injector: Booster parameters

Sources & accelerators Contents > Accelerators > Booster parameters
OPTICS

Structure : FODO with missing magnets

Injection energy (MeV)

Ei

100

Ejection energy (GeV)

Eo

2.75

Circumference (m)

L

156.620

Revolution period (ns)

T

523

Number of super-periods

 

2

Cycling frequency (Hz)

 

3

Emittance (m.rad)*

x

1.5 10-7

Energy dispersion*

sE/E

6.6 10-4

Betatron wave number

nx ; nz

6.4 ;4.4

Momentum compaction

a  

3.12 10-2

Max. values of bx - bz - hx (m)

 

11.5 ; 13.5 ; 1.3

Natural chromaticity

xx ; xz

- 1.14 ; - 1.32

Damping time*(ms)

tx ; tz ; ts

7.5 ; 7.2 ; 3.4

*values at 2.75 GeV

 

 

 

MAGNETS

Dipoles : H shape

Number/nb. of families

36/1

Injection value/ maximal value of the field (T)

0.027 / 0.74

Magnetic length (m)

2.16

Bending radius

12.376

Deviation (°)

10°

Gap (mm)

22

3 Hz Power supply: number x power

Vpeak(V) x Ipeak (A)

(upper and lower coils fed separately)

2 x 65 kVA

1000 x 560

Good field region (mm)

BSC (mm) extraction

48 x 18

60 x 18

Tolerances :

Homogeneity (òDBdl / òBdl) @ x = 48 mm:

Reproducibility magnet to magnet (DòBdl/òBdl)

 

10-3

10-3

Quadrupoles

Number / nb. of families

44 / 2

Max.gradient (T. m-1)

12

Magnetic length (m)

0.4

Bore diameter (mm)

57

3Hz Power supplies: number x power

2 x 20 kVA

Vpeak (V) x Ipeak (A)

450 x 250

Good field region (mm)

52 x 20

BSC (mm)

66 x 20

Tolerances :

 

Homogeneity (òDGdl / òGdl) @ x = 52 mm:

10-3

Reproducibility magnet to magnet (DòGdl/òGdl)

5 10-3

Sextupoles

Number / nb. of families

28 / 2

Max. strength (T.m-2)

16

Magnetic length (m)

0.15

Bore diameter (mm)

60

3 Hz Power supplies:

number x (Vpeak (V) x Ipeak (A)

 

2 x (30 x 30)

Good field region H x V (mm)

50 x 20

Reproducibility

10-2

Correctors

Number H / V

22/22

Max. strength ( T)

0.0030

Gap (mm)

95

Magnetic length (mm)

80

DC power supplies: Vmax (V)x Imax(A)

± 2 x 1.1

DIAGNOSTICS

Nb of BPMs

22

Fluorescent screens

4

Intensity monitors:

1 DCCT + 1 FCT

Beam size measured with synchrotron radiation

1

Tune measurement systems : Striplines

1


 
Fluorescent screen mounted on the vacuum chamber in front of the quadrupole
R.F. SYSTEM

Frequency (MHz)

f

352.202

Harmonic number

h

184

Energy loss by turn (keV) @ 2.75 GeV

U0

407

Nominal peak voltage (kV)

Vinjection

Vextraction

200

850

Number of cavity (5 cells LEP type)

1

Nominal / maximal power of the amplifier (kW)

(solid state)

25; 40

INJECTION/EXTRACTION

Injection kicker

 

Maximal deviation (mrad) (@110 MeV

20

Maximal field (T)

0.01222

Trapeze shape : flat top / falling time (ns)

300 / 200

Aperture (mm x mm)

40 x 16

Magnetic length (m)

0.60

Magnet inductance (µH)

1.8

Ipeak (A)

389

Vcharge (V)

9730

Injection /extraction passive septum

 

Maximal deviation (mrad)

131/9.3

Maximal field (T)

0.161/0.284

Thickness (mm)

3

Pulse shape : 1/2 sine T/2 duration (ms)

60 µs

Aperture (mm x mm)

18 x 15

Magnetic length (m)

0.3

Magnet inductance (µH)

0.950

Ipeak (A)

1922/2924

Extraction kicker

 

Nominal deviation (mrad)

1.5

Field (T)

0.023

Trapeze shape, rising time (ns)

200

Flat top (ns)

300

Aperture (mm x mm)

40 x 16

Magnetic length (m)

0.60

Magnet inductance (µH)

1.8

Ipeak (A)

730

Vcharge (V)

20000

Extraction bumpers (3)

 

Maximal deviation (mrad)

2.5

Maximum field (T)

0.046

Pulse shape : 1/2 sine T/2 duration (ms)

3 to 12

Aperture (mm x mm)

60 x 36

Magnetic length

0.500

Magnet inductance (µH)

225

Ipeak (A)

151.1

Vcharge (V) @ 12 ms duration

14

Extraction active septum

 

Maximal deviation (mrad)

110

Maximum field (T)

1.01

Pulse shape : 1/2 sine T/2 duration (ms)

3.3

Vacuum chamber aperture (mm x mm)

21.2 x 15

Magnetic length

2 x 0.500

Magnet inductance (µH)

7.5

Ipeak (A)

7080

 

BOOSTER Optics
 
 
 
 
 
 
Accueil