RESEARCH ON OUR SITE
 
 

Booster RF System Progress Report

Sources & accelerators Contents > Accelerators > RF Booster Progress Report
Booster RF System Progress Report
Last Update : October 2005
Booster main parameters

Circumference

156.6 m

Revolution frequency

1.91 MHz

Repetition rate

3 Hz

Injection energy, Ei

100 MeV

Final energy, Ef

2.75 GeV

Energy loss / turn @ Ef

410 keV

Beam current (max)

12 mA

RF acceptance @ Ef
@ Ei with Vrf = 200 kV

± 0.35 %
± 1.5 %

Harmonic number

184

RF frequency

352.2 MHz

RF voltage @ Ef

0.85 MV

Beam power @ Ef

5 kW


RF SYSTEM
-> 1CERN-LEP 5-cell Cu cavity, Rs=26 MΩ
Pdis : 15 kW, Pbeam : 5 kW, Ptot : 20 kW

-> 1 solid state amplifier, Pavailable : 35 kW

 

Booster 5-cell Cu cavity (CERN-LEP type)
   
 
  Power coupler 
Booster 35 kW Solid state amplifier
 
147 amplifier modules & DC/DC converters on 8 water-cooled dissipators
Booster amplifier power combination
 
 
Diagram of the Booster RF control system
 
 
Booster Low Level RF Electronics

 

 
3 boucles de contrôle "lent" conventionnelles pour la fréquence, l'amplitude et la phase, conception du LURE adaptée au besoin de SOLEIL


 
Amplitude Phase Fréquence
Précision ± 0.25 % ± 0.4° ± 30 Hz
3 dB BW 12 kHz 7 kHz 5 Hz

 

 

Booster RF power plant: Review of test results and status
Spring 2004: 1st day of operation, amplifier tested up to 35 kw CW on dummy load and then 30 kW for
~ 600 hours without any interruption

June 2004: Cavity RF conditioning up to 30 kW CW (1.5 x Vmax, 3 x <P>)
Several "full reflection" events occured during the conditioning process
-> normal switch-off without trouble for the amplifier


Summer 2004: Implementation of the control (µcontroller + PLC) and LLRF
(drive chain, amplitude, phase and tuning loops)

Autumn 2004: Tests of the complete Booster RF plant (cavity, amplifier, control & LLRF) at 30 kW CW
for more than 1500 h without major trouble nor performance degradation; only a few
minor faults due to cabling mistakes that could be quickly repaired
-> The fault events did not stop neither perturb the amplifier operation

December 2004: Tests with 33 % Preflected (10 over 30kW) in CW for a few days
July 2005: Complete Booster RF plant installed, tested and operational on site
Booster amplifier and cavity inside the test area at LURE
 
 
 
Transfert de la cavité dans l'anneau du Booster
 
 
Cavity accomodated in the Booster ring
 
 
Booster RF room
 
 

Archived Progress Report