This focal spot has been used for the photon beam commissioning. Here we have performed gas phase experiments (M. Meyer, LIXAM) to measure the monochromator resolving power and the total photon flux with a calibrated diode.
First photon beam image at the focal spot registered at the TEMPO beamline
The picture was taken on February 12th 2007 with the monochromator in total reflection mode. The well centered spot is the result of the good work done by the alignment group.
External user equipments can be installed at this focal point:
The PEEM fron Louis Néel Laboratory (Jan Vogel) has been installed on the branch lin in 2008 and 2009 to perform magnetization dynamics experiments.
(a) Initial magnetic domain structure of a 200 nm wide nanowires after applying some magnetic field pulses. (b) Domain structure after application of one 10 ns long current pulse with a current density of 4.2 x 1011 A/m2. The direction of electron flow is indicated in the image. The small white arrows indicate domain walls that have moved, in the direction of the electron flow. The blue arrow points to a new domain that has nucleated. (c) Domain structure after application of an identical pulse, but in the opposite direction. Some of the domain walls, indicated by small white arrows, have moved back in the opposite direction. These data confirm that the domain wall motion is due to the spin torque effect induced by the spin polarized current. However, the domain wall motion is not exactly reversible, indicating the strong role played by domain wall pinning in our system.
Le spectromicroscope NanoESCA (Omicron Nanotechnology) du CEA, permettant la réalisation d’expériences d’XPEEM spectroscopique (i.e, résolues en énergie), a été installé en juillet 2009.
Le filtrage en énergie des images XPEEM se fait grâce à un double analyseur hémisphérique qui, en compensant les aberrations inhérentes à un filtrage classique réalisé à partir d’un seul analyseur, confère au système la haute transmission nécessaire (gain d’un facteur 650) à l’enregistrement d’images à haute résolution énergétique (ΔE jusqu’à 100 meV) formées avec les photoélectrons des niveaux de cœur ou de valence. Cette haute transmission fournit en outre la statistique de comptage nécessaire pour conserver une bonne résolution latérale (Δx=100 nm et moins en imagerie des niveaux de cœur).
Avec cet instrument installé de façon temporaire nous avons effectué les toutes premières expériences d’XPEEM filtré en énergie avec la source SOLEIL.